ICECap
ICECap is a disposable EEG net available in 5 sizes from neonate to adult that you can setup in 10 minutes for hospital or home use
Adaptable
For all ages, from newborns to adults.
Comfortable
Lightweight net allows EEG recording during daily activities.
Disposable
ICECap is a single-use EEG cap, guaranteeing an optimal hygiene and no disinfection or cleaning needed, saving EEG techs valuable time.
Easy to apply
Flexible EEG net for accurate electrode application.
Space-saving
Flat and thin format, easy to store and transport.
Use cases
Routine and long-term EEG studies. For use in hospital environment or at home, the use of our ICECAP® helmets guarantees optimum EEG signal quality for recordings up to 72 hours.
*ICECap Neonate sizes not currently available in North America
Technical Specifications
Neonate XS | Neonate S | Neonate M | ICECap 2 Small | ICECap 2 | |
---|---|---|---|---|---|
Head Circumference | 23 – 31cm | 30 – 38cm | 37 – 51cm | 43 – 53cm | 53 – 60cm |
Supported Montages | Double Distance/Neonatal | Double Distance/Neonatal | Double Distance/Neonatal | Full 10-20 | Full 10-20 |
Electrodes | 11 Ag/AgCl electrodes: 9 EEG channels + ground and reference | 11 Ag/AgCl electrodes: 9 EEG channels + ground and reference | 13 Ag/AgCl electrodes: 11 EEG channels + ground and reference | 21 Ag/AgCl electrodes: 19 EEG channels + ground and reference | 21 Ag/AgCl electrodes: 19 EEG channels + ground and reference |
Landmarks | Placed using Cz | Placed using Cz | Placed using Cz | Placed using 4 built-in adhesives: forehead, occiput, and both temples | Placed using 4 built-in adhesives: forehead, occiput, and both temples |
Duration | 72 hours | 72 hours | 72 hours | 72 hours | 72 hours |
Approvals | CE | CE | CE | CE, FDA | CE, FDA |
Available Regions | Europe | Europe | Europe | North America, Europe | North America, Europe |
Compatibility of ICECap product line in Europe
- Neuronaute : Adaptable with the existing electrode systems on the market (DB25, IceCap, gold cups and subdermal needles) via its interchangeable adapter
- Neuronaute Touchproof adapter : makes the IceCap compatible with all standard touchproof EEG acquisition systems
Connect the ICECap to the Neuronaute to benefit from our prescoring algorithms.
ICECap® is a CE marked class I medical device, according to regulation (UE) 2017/745 and is a Class II medical device according to the classification regulation of the FDA.